Exercise: Measurements And Instrumentation

Questions for: Measurements And Instrumentation

A 1 mA meter is to be converted to 1 A ammeter. The meter resistance is 100 Ω. The value of shunt resistance is
A:
0.001 Ω
B:
0.1001 Ω
C:
100 Ω
D:
1000 Ω
Answer: B

.

If a shunt of 200 Ω resistance is used with a galvanometer of 1000 Ω resistance, the multiplying power is
A:
6
B:
5
C:
1/5
D:
1/6
Answer: A

If current through galvanometer is 1,

A current through shunt = . Total current = 6 I. Hence multiplying factor is 6.

Assertion (A): Strain measurement using strain gauge invariably requires a dummy strain gauge.

Reason (R): The resistance of strain gauge depends on temperature.

A:
Both A and R are true and R is correct explanation of A
B:
Both A and R are true but R is not correct explanation of A
C:
A is true R is false
D:
A is false R is true
Answer: A

The dummy strain gauge compensates the error due to change in temperature because temperature affects both the active and dummy strain gauges equally.

Which of the following instruments can be used for dc as well ac upto a few MHz?
  1. Moving iron instrument
  2. Thermocouple instrument
  3. Induction instrument
  4. Moving coil instrument
Select the correct answer as per following codes
A:
2 only
B:
2 and 3 only
C:
1, 2 and 3 only
D:
2 and 4 only
Answer: A

Thermocouple instrument is based on heating effect and can be used for very high frequencies also.

A moving coil meter has 10 Ω resistance and requires 40 mA for full scale deflection. The shunt resistance required to convert it into 0-2 A ammeter is
A:
0.1021 Ω
B:
0.2041 Ω
C:
0.256 Ω
D:
0.4210 Ω
Answer: B

.